SİMH C2
Ref. Std. VDE 282-15, TS EN 50525-2-83
Construction
Inner Conductor: Electrolytic stranded annealed copper wire (IEC 60228, class 5)
Insulation: Silicon compound, EI2 Core colours
VDE 0293-308 / HD 308 S2 ton be suitable.  
Lay-Up: Isolated cores are bent in layers at proper steps and are fixed
with Polyester tape.
Inner Sheathr: Silicon compounding, EM9, RAL 3000 Red
Screen: Tinned copper braid screen
Sheath: Silicon compounding, EM9, RAL 3000 Brick red
General Features
Flame Test: IEC 60332-1, EN 60332-1, VDE 0482-332-1
Flame Spread: IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24
Halogen/Corrosive Gas Test: IEC 60754-2, EN 50267-2, VDE 0482-267-2
Smoke Density: IEC 61034-2, EN 61034-2, VDE 0482-1034-2
Insulation Continuity(FE): EN 60331, VDE 0472 Part 814
Application
This type of silicon-isolated, encased and screened cables are used as control and feeding cable which are furnished stably in environments with a high ambient temperature, in dry, humid and wet places, in places with an ambient temperature between -60°C … +180°C , in machines and plants which are required to be protected against high electro-magnetic external factors. These cables are also used in instrumentation, control devices and machines, transportation devices and production lines required by project engineering. The screen which is woven with thin tinned copper ensures protection against noises and signals.
Product Data-Sheet
 Click for product PDF file




Copyright © Kastro Kablo - 2015.